Site map+98 21 2201 8011Contact us
Petrochemical industry catalysts

ICD-530 High Temperature Shift Catalyst (HTSC)

High-temperature shift catalyst; converts most of the carbon monoxide in syngas with steam into hydrogen.

High Temperature Shift Catalyst (HTSC)

Where it is used

The process steps where this product is used are highlighted.

Hydrogen units

The hydrogen unit makes, from natural gas or naphtha and steam, the hydrogen that the refinery's treating and hydrocracking units need.

  1. FeedNatural gas or naphtha, and steam
  2. Feed hydrogenationConverts organic sulfur compounds to H₂S.
  3. DesulfurizationZinc oxide absorbs the H₂S.
  4. Steam reforming
  5. High-temperature shift
  6. Low-temperature shift
  7. MethanationIn units that convert the remaining carbon monoxide to methane instead of PSA purification.
  8. OutputHydrogen for treating and hydrocracking units
The order of steps and the catalyst positions are a draft awaiting approval by the technical department.Industry page →

Ammonia and urea units

Natural gas, steam and air become ammonia syngas (hydrogen and nitrogen); ammonia is the feed of the urea plant.

  1. FeedNatural gas, steam and air
  2. Feed hydrogenation
  3. Desulfurization
  4. Primary reforming
  5. Secondary reformingWith process air added, the reforming of the remaining methane with steam is completed and the nitrogen needed for ammonia enters the gas.
  6. High-temperature shift
  7. Low-temperature shift
  8. MethanationRemoves the remaining carbon oxides before ammonia synthesis.
  9. OutputAmmonia syngas for the synthesis reactor
The order of steps and the catalyst positions are a draft awaiting approval by the technical department.Industry page →

Specifications

ShapeTablet
ColourReddish brown to dark brown
Outer diameter5 mm
Height or length5 mm
Bulk density1.10–1.25 kg/L
Radial crush strength≥ 200 N/pellet
Axial crush strength≥ 200 N/pellet
Attrition loss≤ 0.5 wt%
Specific surface area (BET)50–80 m²/g
Pore volume0.25–0.35 cm³/g
Fe₂O₃80.0–88.0 wt%
Cr₂O₃7.0–10.0 wt%
CuO1.5–3.5 wt%
Operating temperature310–360 °C
Operating pressure15–45 bar
Space velocity2000–6000 1/h

These values are awaiting final approval by the technical department; ask us for the official data sheet.

The technical and safety data sheets of this product are sent on request. Request the technical or safety data sheet

Talk to our engineers about the right catalyst for your unit.