Steel industry catalysts
ICD-710 Sulfur Adsorbent
Zinc-oxide adsorbent that removes sulfur from the feed gas of direct-reduction plants, ahead of the reformer.

Where it is used
The process steps where this product is used are highlighted.
Direct reduction of iron units
In the reformer of a direct-reduction plant, natural gas and recycled top gas from the furnace are turned into reducing gas, which reduces iron ore pellets to sponge iron.
- FeedNatural gas and recycled top gas from the reduction furnace
- Feed gas desulfurizationThe zinc-oxide (ZnO) adsorbent takes up the sulfur compounds in the feed gas before it enters the reformer, so that the reformer catalyst is not poisoned.
- ReformerThe reformer tubes are filled from bottom to top with layers of inert, semi-active and active catalyst; ICD-120 and ICD-130 are for PERED plants.
- OutputReducing gas (hydrogen and carbon monoxide) for the reduction furnace
Specifications
| Shape | Extrudate | |
| Colour | White to cream | |
| Height or length | 9–15 mm | |
| Bulk density | 1.1–1.3 kg/L | |
| Specific surface area (BET) | 30–40 m²/g | |
| Pore volume | 0.22 ± 0.04 cm³/g | |
| ZnO | 88–92 wt% | |
| CoO | Trace wt% | |
| NiO | Trace wt% | |
| MoO₃ | Trace wt% | |
| Operating temperature | 360–400 °C | |
| Sulfur pick-up capacity | 30 wt% S | |
| Space velocity | 2000 1/h | |
| Storage | Keep dry |
These values are awaiting final approval by the technical department; ask us for the official data sheet.
Documents
All documents →- ICD-C-01ICD product catalogue (Persian edition)Catalogue · PDF · 6.9 MB
The technical and safety data sheets of this product are sent on request. Request the technical or safety data sheet